Authorised dealer for Yuken and CoolAce +91 94825 45346+91 98454 43145marketing@shreehydraulics.com

Yuken vane pumps

PV2R Series double vane pumps

Catalogue-backed information for Yuken PV2R12, PV2R13 and PV2R23 double vane pumps.

3 familiesPV2R12, PV2R13 and PV2R23
210Kgf/cm² for specified sizes with anti-wear petroleum oil; see limits below
600-1800r/min. overall petroleum-oil range; model-specific limits below
2 discharge portsOutput for separate circuits

Two pump sections driven by one common shaft

Yuken PV2R double vane pumps combine two PV2R single pumps in tandem within one housing. A common shaft drives both sections. One suction port and two discharge ports allow output flow to be supplied to separate circuits.

Yuken PV2R Series double vane pump

Product photograph from the official Yuken India catalogue. Confirm the exact configuration when ordering.

Choose the model for the required operating range

PV2R12

750-1800 r/min.

Petroleum base oil shaft-speed range. Flange or foot mounting. Confirm the small-volume and large-volume pump combination against the complete model code.

PV2R13

750-1800 r/min.

Petroleum base oil shaft-speed range. Displacement-specific suction-pressure limits apply at higher speeds.

PV2R23

600-1800 r/min.

Petroleum base oil shaft-speed range. Displacement-specific suction-pressure limits apply at higher speeds.

SeriesPetroleum base oilsWater-containing and phosphate ester fluidsApprox. massMounting
PV2R12750–1800 r/min.750–1200 r/min.25 Kg. flange; 29.3 Kg. footFlange or foot
PV2R13750–1800 r/min.750–1200 r/min.45.6 Kg. flange; 55.6 Kg. footFlange or foot
PV2R23600–1800 r/min.600–1200 r/min.51 Kg. flange; 61 Kg. footFlange or foot

The catalogue lists the following operating speed ranges. Maximum speed remains subject to the suction-pressure requirements and displacement-specific notes below. Source: Yuken India catalogue, printed pages 142–143. Ratings apply to the stated fluid types and catalogue conditions, not every installation.

Pressure and suction conditions

Maximum operating pressure depends on nominal displacement and fluid type. With anti-wear petroleum base oil, the catalogue lists 210 Kgf/cm² for nominal sizes 6, 8, 10, 12, 14, 17, 19, 23, 25, 26, 33, 41, 47, 53, 59, 65, 52, 60, 66, 76 and 94 cm³/rev., and 160 Kgf/cm² for 31 and 116 cm³/rev. For the 6 cm³/rev. size, operation above 160 Kgf/cm² requires a speed over 1450 r/min.

Do not apply the anti-wear oil rating to other fluids. R & O oils, water-containing fluids and phosphate esters have separate limits in the catalogue. Phosphate ester use requires special seals and manufacturer consultation.

For PV2R13 and PV2R23 with the 116 nominal displacement large section, minimum suction pressure is −0.2 Kgf/cm² below 1700 r/min. and 0 Kgf/cm² at 1700–1800 r/min. For PV2R23 with 76 or 94, the corresponding limits are −0.2 and −0.07 Kgf/cm².

PV2R12 also has a combined input-power limit that depends on shaft speed. Confirm both pump-section loads against the manufacturer's data before selecting the drive.

Model configuration and spare-parts notes

The catalogue specifies F for flange mounting and L for foot mounting. R denotes clockwise rotation viewed from the shaft end. Consult Yuken for anti-clockwise rotation and confirm suction and discharge port positions before ordering.

Choose the small-volume and large-volume sections together. The catalogue's PV2R12 designation table and combination chart show different sets of sizes. We will confirm the complete requested combination with Yuken before quoting; the charts are not a stock or availability list.

Cartridge and seal-kit references are included on printed page 151. Share the complete pump code when requesting spares. Yuken advises consulting the manufacturer for cartridge replacement instructions.

Selection information

Details to confirm before quotation

Send the full model code or a clear nameplate photograph, the required flow and pressure for each circuit, operating speed, fluid type and mounting details.

  • PV2R12, PV2R13 or PV2R23 series
  • Small-volume and large-volume pump sections
  • Flange or foot mounting
  • Rotation viewed from the shaft end
  • Suction and discharge port positions
  • Fluid type, operating pressure, shaft speed and quantity

Download the PV2R Series double-pump catalogue

Review the official Yuken India document for model coding, operating limits, mounting dimensions, cartridge kits and seals.

Download PDF

Send your PV2R double-pump requirement

Contact Shree Hydraulics with your model code and operating requirements. We will help confirm the configuration, availability and quotation.

Request a quote