Yuken power saving directional valves
PS-DSG-01 power saving valves
Review the PS-DSG-01 hydraulic ratings and D12 or D24 coil options. Confirm the full valve code and connector arrangement for a new valve or retrofit enquiry.
Reduce current after the valve shifts

PS-DSG-01 automatically lowers the holding current after valve shifting, reducing the power drawn by the solenoid during the holding stage.
The manufacturer describes it as an add-on to DSG-01 **50 series solenoid operated directional valves. Interchangeable adapters can be ordered separately for suitable retrofit installations.
Send the complete existing valve and coil codes before selecting a retrofit. Confirm the connector arrangement and electrical ratings for the specific installation.
Hydraulic and switching ratings
| Parameter | PS-DSG-01 rating |
|---|---|
| Maximum flow | 40 lpm |
| Maximum operating pressure | 250 kgf/cm² |
| Maximum T-line back pressure | 160 kgf/cm² |
| Maximum changeover frequency | 60 cycles/min |
Use the complete valve designation to confirm spool function and configuration. These ratings are from the PS-DSG brochure and should be checked against the selected assembly.
Compare D12 and D24 coils
| Parameter | D12 | D24 |
|---|---|---|
| Source rating | 12 V | 24 V |
| Serviceable voltage range | 10.8–13.2 V | 21.6–26.4 V |
| Startup current | 2.2 A | 1.1 A |
| Holding current | 0.68 A | 0.34 A |
| Power | 8 W | 8 W |
The brochure lists current and power at rated voltage. Check the power supply, coil and adapter combination before ordering.
Selection support
Send your PS-DSG-01 requirement
Identify whether you need a valve assembly or an adapter for an existing installation.
- Full valve model and coil nameplate photograph
- D12 or D24 coil and supply voltage
- Spool function and required flow
- Operating pressure and T-line back pressure
- Connector photograph and switching frequency
- Quantity and required timing
PS-DSG technical brochure
Review hydraulic ratings, coil data, the assembly illustration and startup-to-holding behaviour.
Enquire about PS-DSG-01
Send your valve code, coil details and quantity to Shree Hydraulics.