Products / Yuken hydraulic products / Cartridge valves / RVC40 Pilot Operated Pressure Reducing Valve

Yuken pressure-reducing cartridge

RVC40 Pilot Operated Pressure Reducing Valve

A pilot-operated cartridge that reduces inlet pressure at port 2 to a lower controlled pressure at port 1.

40 L/min.Rated flow
350 Kgf/cm²Maximum operating pressure
3Pressure-range codes
N / VSeal options

Function and model selection

Yuken RVC40 Pilot Operated Pressure Reducing Valve shown in the manufacturer catalogue
Manufacturer catalogue image. Configuration varies with the full model designation.

RVC40 provides a pressure-reducing function for circuits requiring different pressure levels from one pump. Its drawing identifies port 1 as reduced pressure, port 2 as inlet and port 3 as drain.

A pilot-operated cartridge that reduces inlet pressure at port 2 to a lower controlled pressure at port 1.

Use the model comparisons below with the linked manufacturer catalogue. Send the complete designation and application details for selection support.

Model comparison

Range codePressure adjustment (Kgf/cm²)Seal codes
A3.5-105N: Nitrile / V: Viton
B7-210N: Nitrile / V: Viton
W10-315N: Nitrile / V: Viton

Adjustment ranges above follow the model-number designation in EI.V4.0237. Select the range code for the required reduced pressure; the full family range does not apply to every model.

Configuration and ordering

Pressure-range selection

The designation combines RVC, size 40, the A, B or W pressure-range code and the N or V seal code. Include the required inlet and reduced pressures with your enquiry.

Cavity and drain arrangement

Use the manufacturer's cavity drawing and installation dimensions to confirm the manifold interface. Include the drain arrangement and hydraulic circuit when requesting selection support.

Selection support

Send the complete valve requirement

Include the valve designation, cavity drawing and operating requirements to help confirm the correct configuration.

  • Complete valve model and design number
  • Required valve function and flow
  • Operating pressure and required setting
  • Cavity, pilot, ports and drain details
  • Hydraulic circuit and installation drawing
  • Nameplate photograph and quantity

Manufacturer catalogue

Specifications, model designations, cavity drawings and configuration details for RVC40 Pilot Operated Pressure Reducing Valve.

Download catalogue

Enquire about RVC40 Pilot Operated Pressure Reducing Valve

Send your model code and application details to Shree Hydraulics in Belagavi for selection and quotation enquiries across India.

Request a quote