Authorised dealer for Yuken and CoolAce +91 94825 45346+91 98454 43145marketing@shreehydraulics.com

Yuken vane pumps

SVP Series double vane pumps

Catalogue-backed specifications for Yuken SVP12 and SVP23 fixed-displacement double vane pumps.

2 familiesSVP12 and SVP23
210Kgf/cm² listed maximum operating pressure
600-2000r/min. listed shaft-speed range
2 discharge portsFor separate or common circuits

Two pump sections driven by one common shaft

SVP Series double vane pumps combine two SVP single-pump sections in tandem within one housing. Fluid from the two separate discharge ports can be supplied to separate or common circuits.

SVP12 combines SVP1 and SVP2 sections. SVP23 combines SVP2 and SVP3 sections and is identified in the catalogue for mobile applications.

Choose the combination for the required displacement range

SVP12

SVP1 + SVP2

Small-pump nominal displacements: 3, 5, 7, 8, 10, 13, 14 and 26. Large-pump nominal displacements: 11, 17, 22, 25, 30, 33, 38, 43 and 47.

SVP23

SVP2 + SVP3

Small-pump nominal displacements: 11, 17, 22, 25, 30, 33, 38, 43 and 47. Large-pump nominal displacements: 50, 58, 75, 92, 117 and 142.

SeriesMaximum operating pressureShaft-speed rangeApprox. massMounting
SVP12210 Kgf/cm²600-2000 r/min.*18.75 Kg. flange; 22 Kg. footFlange or foot
SVP23210 Kgf/cm²600-2000 r/min.*43 Kg. flange; 49.5 Kg. footFlange or foot

* For speeds above 1500 r/min., the manufacturer catalogue instructs users to consult the factory. Values must be checked against the complete model designation.

Selection information

Details to confirm before quotation

Send the complete model code or a clear nameplate photograph. If the designation is unavailable, include the required displacement from both pump sections and the operating requirement.

  • SVP12 or SVP23 series
  • Nominal displacement for both pump sections
  • Flange or foot mounting
  • Clockwise or anticlockwise rotation, viewed from the shaft end
  • Discharge and suction port positions
  • Hydraulic fluid, operating pressure, shaft speed and quantity

Download the SVP Series double-pump catalogue

Review the supplied Yuken document for model coding, mounting dimensions, cartridge kits and seal information.

Download PDF

Send your SVP double-pump requirement

Include the complete model, both nominal displacements, quantity and operating details. A clear nameplate photograph can help with identification.

Request a quote