PV2R12
750-1800 r/min.Petroleum base oil shaft-speed range. Flange or foot mounting. Confirm the small-volume and large-volume pump combination against the complete model code.
Yuken vane pumps
Catalogue-backed information for Yuken PV2R12, PV2R13 and PV2R23 double vane pumps.
Yuken PV2R double vane pumps combine two PV2R single pumps in tandem within one housing. A common shaft drives both sections. One suction port and two discharge ports allow output flow to be supplied to separate circuits.

Product photograph from the official Yuken India catalogue. Confirm the exact configuration when ordering.
Petroleum base oil shaft-speed range. Flange or foot mounting. Confirm the small-volume and large-volume pump combination against the complete model code.
Petroleum base oil shaft-speed range. Displacement-specific suction-pressure limits apply at higher speeds.
Petroleum base oil shaft-speed range. Displacement-specific suction-pressure limits apply at higher speeds.
| Series | Petroleum base oils | Water-containing and phosphate ester fluids | Approx. mass | Mounting |
|---|---|---|---|---|
| PV2R12 | 750–1800 r/min. | 750–1200 r/min. | 25 Kg. flange; 29.3 Kg. foot | Flange or foot |
| PV2R13 | 750–1800 r/min. | 750–1200 r/min. | 45.6 Kg. flange; 55.6 Kg. foot | Flange or foot |
| PV2R23 | 600–1800 r/min. | 600–1200 r/min. | 51 Kg. flange; 61 Kg. foot | Flange or foot |
The catalogue lists the following operating speed ranges. Maximum speed remains subject to the suction-pressure requirements and displacement-specific notes below. Source: Yuken India catalogue, printed pages 142–143. Ratings apply to the stated fluid types and catalogue conditions, not every installation.
Maximum operating pressure depends on nominal displacement and fluid type. With anti-wear petroleum base oil, the catalogue lists 210 Kgf/cm² for nominal sizes 6, 8, 10, 12, 14, 17, 19, 23, 25, 26, 33, 41, 47, 53, 59, 65, 52, 60, 66, 76 and 94 cm³/rev., and 160 Kgf/cm² for 31 and 116 cm³/rev. For the 6 cm³/rev. size, operation above 160 Kgf/cm² requires a speed over 1450 r/min.
Do not apply the anti-wear oil rating to other fluids. R & O oils, water-containing fluids and phosphate esters have separate limits in the catalogue. Phosphate ester use requires special seals and manufacturer consultation.
For PV2R13 and PV2R23 with the 116 nominal displacement large section, minimum suction pressure is −0.2 Kgf/cm² below 1700 r/min. and 0 Kgf/cm² at 1700–1800 r/min. For PV2R23 with 76 or 94, the corresponding limits are −0.2 and −0.07 Kgf/cm².
PV2R12 also has a combined input-power limit that depends on shaft speed. Confirm both pump-section loads against the manufacturer's data before selecting the drive.
The catalogue specifies F for flange mounting and L for foot mounting. R denotes clockwise rotation viewed from the shaft end. Consult Yuken for anti-clockwise rotation and confirm suction and discharge port positions before ordering.
Choose the small-volume and large-volume sections together. The catalogue's PV2R12 designation table and combination chart show different sets of sizes. We will confirm the complete requested combination with Yuken before quoting; the charts are not a stock or availability list.
Cartridge and seal-kit references are included on printed page 151. Share the complete pump code when requesting spares. Yuken advises consulting the manufacturer for cartridge replacement instructions.
Selection information
Send the full model code or a clear nameplate photograph, the required flow and pressure for each circuit, operating speed, fluid type and mounting details.
Review the official Yuken India document for model coding, operating limits, mounting dimensions, cartridge kits and seals.
Compare the single-pump range and its catalogue-backed selection information.
Contact Shree Hydraulics with your model code and operating requirements. We will help confirm the configuration, availability and quotation.