Adjustment and design
The catalogue uses design number 41. Standard threaded models use the 4180 suffix, while SRCG models use 41. A hand knob type is listed on request; include this requirement for confirmation.
Yuken throttle and check valves
Adjust actuator speed where line pressure is almost steady and some flow variation is acceptable. Compare threaded and sub-plate models with free reverse flow.

SRCT and SRCG valves throttle hydraulic flow to regulate actuator speed. The manufacturer specifies their use where line pressure is almost steady and small changes in flow caused by pressure variations are acceptable.
The integrated check valve permits free reverse flow from the outlet port to the inlet port. The controlled-flow direction and reverse-flow direction are identified in the mounting drawings.
SRCT-03 and SRCT-06 use threaded connections. SRCG-06 uses sub-plate mounting. Choose the H or L option for the required pressure differential across the valve.
| Model | Mounting | Rated flow | Maximum operating pressure | Mass |
|---|---|---|---|---|
| SRCT-03 | Threaded | 30 L/min. | 210 Kgf/cm² | 1.2 Kg. |
| SRCT-06 | Threaded | 85 L/min. | 210 Kgf/cm² | 3.2 Kg. |
| SRCG-06 | Sub-plate | 85 L/min. | 210 Kgf/cm² | 4.0 Kg. |
Rated flow is the approximate flow with the valve fully open at a maximum inlet-to-outlet pressure drop of 3 Kgf/cm², fluid specific gravity 0.85 and kinematic viscosity 20 cSt (100SSU). It is not a constant-flow guarantee across changing pressure conditions.
| Symbol | Option | Pressure differential |
|---|---|---|
| H | High pressure differential | 50 ~ 210 Kgf/cm² |
| L | Low pressure differential | 5 ~ 50 Kgf/cm² |
Differential pressure is the pressure difference across the valve. Review the metered-flow-versus-adjustment-revolutions curves for the selected option and the separate reverse free-flow pressure-drop curves.
The catalogue uses design number 41. Standard threaded models use the 4180 suffix, while SRCG models use 41. A hand knob type is listed on request; include this requirement for confirmation.
An F prefix identifies seals for phosphate ester type fluids. Consult Yuken before ordering special seals and include the fluid details with your enquiry.
| Model | Connection or sub-plate | Thread size |
|---|---|---|
| SRCT-03 | Threaded inlet and outlet | 3/8 BSP.F |
| SRCT-06 | Threaded inlet and outlet | 3/4 BSP.F |
| SRCG-06 | SRGM-06-4080 | 3/4 BSP.F |
| SRCG-06 | SRGM-06X-4080 | 1 BSP.F |
The SRCG-06 mounting bolt kit is BKSRG-06-40, with four M10 x 70 Lg. socket head cap screws. Confirm the mounting dimensions and port orientation against the full catalogue drawing.
Selection support
Include the inlet and outlet pressures so the differential-pressure option can be reviewed with the required actuator speed.
Review rated-flow conditions, adjustment curves, reverse-flow pressure drops and installation dimensions.
Review FG and FCG for pressure- and temperature-compensated flow control.
Send your model and circuit details to Shree Hydraulics in Belagavi for product selection and quotation enquiries across India.