Pilot arrangement
The catalogue lists internal- and external-pilot versions. Confirm the circuit, pilot supply and full valve designation.
EH Series with on-board electronics
Select metered flow, check-valve function and pilot connection.

EHFG and EHFCG provide proportional flow control through an input-voltage command. Pressure and temperature compensation are included; EHFCG adds the check-valve flow path.
Select metered flow, check-valve function and pilot connection.
Use the model comparisons below with the linked manufacturer catalogue. Send the complete designation and application details for selection support.
| Model size and flow code | Metered-flow range, L/min. | Pressure limit, Kgf/cm² |
|---|---|---|
| 03-60 | 1–60 | 210 |
| 03-125 | 1–125 | 210 |
| 06-250 | 2.5–250 | 250 |
The minimum differential pressure is 10 Kgf/cm². Check-valve free flow is 130 L/min. for size 03 and 280 L/min. for size 06.
The catalogue lists internal- and external-pilot versions. Confirm the circuit, pilot supply and full valve designation.
Maximum metered flow corresponds to a 5 V DC command. Confirm the controller signal, power supply and connector arrangement for the chosen model.
Selection support
Include the existing model label and circuit or wiring details so the valve and electronics can be checked together.
Specifications, model designations, installation drawings and electrical details for EHFG and EHFCG flow control valves.
Browse E Series, EH Series and the associated amplifiers and controllers.
Send your model code and application details to Shree Hydraulics in Belagavi for selection and quotation enquiries across India.