Pilot and check options
Select EFG or EFCG and the required metered-flow code. The 10Ω Series includes internal- and external-pilot configurations.
E Series flow control
Distinguish the coil family, metered-flow range and check-valve function.

EFG controls metered flow in proportion to amplifier current. EFCG adds a check-valve flow path. The catalogue covers pressure- and temperature-compensated 40Ω Series and 10Ω Series versions.
Distinguish the coil family, metered-flow range and check-valve function.
Use the model comparisons below with the linked manufacturer catalogue. Send the complete designation and application details for selection support.
| Family and size | Metered flow, L/min. | Pressure limit, Kgf/cm² |
|---|---|---|
| 40Ω Series, 02 | 0.3–10 or 0.3–30 | 210 |
| 40Ω Series, 03 | 2–60 or 2–125 | 210 |
| 40Ω Series, 06 | 3–250 | 210 |
| 40Ω Series, 10 | 5–500 | 210 |
| 10Ω Series, 03 | 1–60 or 1–125 | 210 |
| 10Ω Series, 06 | 2.5–250 | 250 |
The catalogue calls the first family 40Ω Series but specifies a 45Ω coil resistance. Confirm the actual coil and design number when matching the amplifier.
Select EFG or EFCG and the required metered-flow code. The 10Ω Series includes internal- and external-pilot configurations.
Pressure compensation requires a minimum inlet-to-outlet differential pressure. Review the size-specific limits, free-flow rating and pilot requirements in the catalogue.
Selection support
Include the existing model label and circuit or wiring details so the valve and electronics can be checked together.
Specifications, model designations, installation drawings and electrical details for EFG and EFCG flow control valves.
Browse E Series, EH Series and the associated amplifiers and controllers.
Send your model code and application details to Shree Hydraulics in Belagavi for selection and quotation enquiries across India.