Confirm the complete unit code
Select pump, pressure setting, reservoir and motor together using the catalogue model table. The family prefix alone does not define the operating flow, pressure or electrical requirements.
Yuken fixed vane-pump units
Standard hydraulic power packs with PVR1T fixed displacement vane pumps.

The YIP family uses a fixed displacement vane pump. Selection requires the required flow and pressure, a suitable motor and reservoir, and the valve circuit for the machine.
Standard hydraulic power packs with PVR1T fixed displacement vane pumps.
Use the model comparisons below with the linked manufacturer catalogue. Send the complete designation and application details for selection support.
| Unit prefix | Pump option | Displacement |
|---|---|---|
| YIP-4 | PVR1T-4 | 4 cc/rev |
| YIP-8 | PVR1T-8 | 7.8 cc/rev |
| YIP-10 | PVR1T-10 | 9.5 cc/rev |
| YIP-15 | PVR1T-15 | 14.6 cc/rev |
| YIP-17 | PVR1T-17 | 16 cc/rev |
Confirm the full unit combination using catalogue pages 7–8. Pump pressure-adjustment ranges must not be treated as the operating-pressure rating of every complete power pack.
Select pump, pressure setting, reservoir and motor together using the catalogue model table. The family prefix alone does not define the operating flow, pressure or electrical requirements.
Specify the valve circuit and required manifold, oil pan, temperature gauge, float switch or terminal box. Options depend on tank size and unit configuration; use the catalogue option matrix to confirm the combination.
Selection support
Include the existing unit model or hydraulic circuit, operating requirements and available installation space.
Specifications, model designations, installation drawings and configuration details for YIP Series standard power packs.
Browse YIA, YIV and YIP standard power packs and YCPU compact units.
Send your model code and application details to Shree Hydraulics in Belagavi for selection and quotation enquiries across India.