Pilot and compensation
Choose internal or external pilot, spool type and whether the relief-type pressure compensator is required. The CB option denotes the compensator.
EH Series with LVDT feedback
Select the pilot and pressure-compensator arrangement for the high-response family.

EHDFG-04 and EHDFG-06 combine an LVDT and amplifier inside the valve for internal closed-loop spool control. They form a separate high-response family from the EHDFG-01 and 03 valves.
Select the pilot and pressure-compensator arrangement for the high-response family.
Use the model comparisons below with the linked manufacturer catalogue. Send the complete designation and application details for selection support.
| Model | Rated flow, L/min. | Pilot flow at transition, L/min. |
|---|---|---|
| EHDFG-04 | 130 | 6 |
| EHDFG-06 | 280 | 10 |
Rated flow is specified at valve ΔP 15 Kgf/cm². Minimum pilot pressure is 15 Kgf/cm² and maximum drain-line back pressure is 1 Kgf/cm².
Choose internal or external pilot, spool type and whether the relief-type pressure compensator is required. The CB option denotes the compensator.
The catalogue specifies ±24 V DC supply, with a ±21 to ±28 V DC range including ripple. Rated flow corresponds to a ±5 V DC command; confirm the dual-polarity supply arrangement.
Selection support
Include the existing model label and circuit or wiring details so the valve and electronics can be checked together.
Specifications, model designations, installation drawings and electrical details for EHDFG-04 and 06 high-response valves.
Browse E Series, EH Series and the associated amplifiers and controllers.
Send your model code and application details to Shree Hydraulics in Belagavi for selection and quotation enquiries across India.