Model options
Specify EDG-01, pressure range, general-use or vent-control arrangement, safety-valve option and orifice designations.
E Series proportional pressure control
Compare pressure ranges and safety-valve options for low-flow pilot pressure control.

EDG-01 combines a proportional DC solenoid with a direct-acting relief valve. Input current controls pressure for low-flow circuits or the pilot stage of a proportional hydraulic control valve.
Compare pressure ranges and safety-valve options for low-flow pilot pressure control.
Use the model comparisons below with the linked manufacturer catalogue. Send the complete designation and application details for selection support.
| Pressure code | Adjustment range, Kgf/cm² | Rated current |
|---|---|---|
| B | 5–70 | 800 mA |
| C | 10–160 | 900 mA |
| H | 12–250 | 950 mA |
These ratings apply to the EDG-01 design shown in the linked catalogue. Maximum tank-line back pressure is 2 Kgf/cm².
Specify EDG-01, pressure range, general-use or vent-control arrangement, safety-valve option and orifice designations.
Use an applicable proportional amplifier. Vent-control applications need the circuit and pipe arrangement checked against the manufacturer instructions.
Selection support
Include the existing model label and circuit or wiring details so the valve and electronics can be checked together.
Specifications, model designations, installation drawings and electrical details for EDG pilot relief valves.
Browse E Series, EH Series and the associated amplifiers and controllers.
Send your model code and application details to Shree Hydraulics in Belagavi for selection and quotation enquiries across India.