Complete model designation
Confirm size, cover type, high-vent option, coil voltage, electrical connection and manual override. The model designation lists design number 12 and N1 plug-in connection. Code 0 omits the solenoid operated valve.
Yuken Solenoid-controlled pressure relief
Select unloading, two-pressure or three-pressure control arrangements with the appropriate LBS cover and solenoid configuration.

LBS combines a relief logic valve with solenoid controlled directional and pilot relief controls. Depending on the cover configuration, the assembly provides unloading or multiple-pressure control.
The catalogue lists LBS-16, LBS-25, LBS-32 and LBS-50. Cover choice determines the pressure-control function, so a valve size alone is not a complete ordering specification.
Confirm the complete cartridge, cover and manifold arrangement against the catalogue installation drawings.
| Model | Maximum flow, L/min. | Minimum flow, L/min. |
|---|---|---|
| LBS-16 | 125 | 5 |
| LBS-25 | 250 | 5 |
| LBS-32 | 500 | 8 |
| LBS-50 | 1200 | 10 |
Above 250 Kgf/cm², the catalogue requires flow above 15 L/min. for every model. The listed minimum flows otherwise vary by size.
Maximum operating pressure for the listed models: 315 Kgf/cm².
| Code | Catalogue function |
|---|---|
| 0 | Without solenoid operated valve |
| 1 | Normally closed, for unloading |
| 2 | Normally open, for unloading |
| 3 | Normally closed, with vent restrictor |
| 4 | Normally open, with vent restrictor |
| 5 | Two-pressure control |
| 6 | Three-pressure control |
| 7 | Two-pressure control and unloading |
Cover codes identify different pilot circuits. Review the corresponding hydraulic symbol before confirming a configuration.
Confirm size, cover type, high-vent option, coil voltage, electrical connection and manual override. The model designation lists design number 12 and N1 plug-in connection. Code 0 omits the solenoid operated valve.
The pressure-adjustment range is 4 - 315 Kgf/cm². The catalogue identifies A, D and R coil types for AC, DC and AC to DC rectified supply respectively; confirm the full voltage designation and the cover's pilot-valve spool type.
Selection support
A full model code, nameplate photograph and circuit drawing help identify the required assembly.