Authorised dealer for Yuken and CoolAce +91 94825 45346+91 98454 43145marketing@shreehydraulics.com

Yuken Solenoid-operated directional control

LDS Series logic valves

Compare LDS valve sizes, normally open or closed covers and electrical options for solenoid-operated pilot control.

5 sizesCatalogue model range
315 Kgf/cm²Maximum operating pressure
350 to 2100L/min. rated flow by size
2:1Poppet-area ratio

Solenoid-operated directional control

Yuken LDS logic valve shown in the manufacturer catalogue
Manufacturer illustration of the LDS family. The supplied configuration depends on the complete model code.

LDS combines a logic valve for the main circuit with a solenoid operated directional valve that switches the pilot lines. Select the main valve size and pilot-control arrangement as one assembly.

The current linked catalogue lists LDS-25, LDS-32, LDS-40, LDS-50 and LDS-63. Its cover options include normally closed and normally open arrangements, with additional shuttle-valve circuits.

Confirm the complete cartridge, cover and manifold arrangement against the catalogue installation drawings.

Models and rated flow

ModelRated flow, L/min.
LDS-25350
LDS-32500
LDS-40850
LDS-501400
LDS-632100

Rated flow is specified at a pressure drop of 3 Kgf/cm² with fluid viscosity 35cSt. Confirm the selected cover's circuit symbol rather than relying only on its normally open or closed description.

Maximum operating pressure for the listed models: 315 Kgf/cm².

Pilot cover arrangements

CodeCatalogue function
1Normally closed
2Normally open
3 and 5Normally closed with shuttle valve; circuit symbols differ
4 and 6Normally open with shuttle valve; circuit symbols differ

Cover codes identify different pilot circuits. Review the corresponding hydraulic symbol before confirming a configuration.

Ordering and configuration

Complete model designation

Confirm the valve size, cracking pressure, poppet cushion, cover circuit, orifice and electrical specification. The O option denotes supply without the solenoid operated valve; it must not be confused with the complete assembly.

Pilot and switching options

The catalogue identifies A for AC, D for DC, R for AC to DC rectified and RQ for rectified quick-return coils. Confirm the complete voltage code, terminal-box or N1 plug-in connection, and manual-override option before quotation.

Selection support

Confirm the valve and pilot circuit

A full model code, nameplate photograph and circuit drawing help identify the required assembly.

  • Valve family, size and complete model code
  • Operating pressure and required flow
  • Cover type, pilot passages and orifice details
  • Poppet cushion and cracking-pressure option
  • Coil voltage, electrical connection and manual override
  • Hydraulic fluid, seal requirements and quantity

LDS logic valve catalogue

Open the LDS section of the full Yuken logic valve catalogue for specifications, symbols and installation details.

Download catalogue

Enquire about LDS logic valves

Send your model code and circuit details to Shree Hydraulics in Belagavi for product selection and quotation enquiries across India.

Request a quote