Authorised dealer for Yuken and CoolAce +91 94825 45346+91 98454 43145marketing@shreehydraulics.com

Yuken stackable hydraulic controls

06 Series modular valves

Select 06 Series reducing, throttle and check, and pilot operated check valves with the correct directional-valve interface and stack sequence.

3/4Catalogue valve size
500 L/min.Maximum flow; model limits apply
250 Kgf/cm²General series pressure rating
1 to 5Stack count includes the directional valve

Choose the controls for your circuit

Yuken 06 Series modular valves shown in the manufacturer catalogue
06 Series product illustration from the Yuken manufacturer catalogue.

The 06 Series combines pressure, flow and check functions in a bolted modular assembly. Yuken lists applications in machine tools, special purpose machines, presses, steel mill equipment and ships.

The mounting surface is ISO 4401-AE-08-4-A. The catalogue describes use with solenoid controlled pilot operated directional valves such as DSHG-06, subject to specific model restrictions.

A matching mounting surface alone does not confirm circuit compatibility. Review every valve's function, flow limit and pressure rating as part of the complete stack.

Series specifications and mounting

Detail06 Series
Valve size3/4
General series maximum operating pressure250 Kgf/cm²
Maximum flow500 L/min., subject to individual valve and pressure-setting limits
Mounting surfaceISO 4401-AE-08-4-A
Number of stacks1 to 5, including the directional valve
Sub-plate familyDHGM-06
Mounting bolt-kit familyMBK-06

The catalogue's general series rating is 250 Kgf/cm², while its reducing-valve table separately lists 350 Kgf/cm². This does not establish a 350 Kgf/cm² rating for a complete stack; confirm the selected assembly with Yuken.

Model families and controlled lines

FunctionModel familiesSelection detail
ReducingMRP-06 / MRA-06 / MRB-06P / A / B respectively
Throttle and checkMSA-06 / MSB-06 / MSW-06A / B / A&B respectively; X for metre-out, Y for metre-in
Pilot operated checkMPA-06 / MPB-06 / MPW-06A / B / A&B respectively; confirm pilot and drain arrangement

Select the complete model designation from the catalogue, including the applicable pressure or cracking-pressure code, flow direction, seal option and design number.

Check individual valve limits

FamilyCatalogue pressure ratingCatalogue maximum flow
Reducing valves350 Kgf/cm²A-range: 125 L/min.; B/C/H ranges: up to 500 L/min.
Throttle and check valves250 Kgf/cm²500 L/min.
Pilot operated check valves250 Kgf/cm²500 L/min.

For A- and B-range reducing valves, maximum flow is limited by secondary pressure. The specifications table includes an A-range entry, but the model-designation table lists B, C and H; confirm A-range ordering availability directly with Yuken.

Confirm the complete assembly

Mounting hardware

The catalogue lists DHGM-06 sub-plates and MBK-06 mounting bolt kits. Select the kit for the actual stack height and design number, and follow the manufacturer's assembly and tightening instructions.

Directional-valve compatibility

The catalogue excludes pressure-centred directional valves (3H types) and models with pilot pistons (P types) from these modular combinations because the required V and W drain ports are not provided. Confirm the complete directional-valve designation before ordering.

Yuken provides stacking-sequence diagrams for reducing valves with throttle and check valves, and for pilot operated check valves with throttle and check valves. Follow those diagrams and confirm pilot and drain connections.

Phosphate ester fluids require the catalogue's special-seal configuration. Consult Yuken before ordering special seals.

Selection support

Send the complete stack requirement

Share a circuit drawing or clear nameplate photographs so the required functions and configuration can be checked.

  • Complete valve and directional-valve codes
  • Controlled lines and pressure settings
  • Required flow and metre-in or metre-out arrangement
  • Pilot and drain connections
  • Stack sequence, mounting plate and bolt kit
  • Hydraulic fluid, seal requirements and quantity

06 Series modular valve catalogue

Review ratings, circuit symbols, ordering codes, mounting details and dimensions.

Download catalogue

Enquire about 06 Series modular valves

Send your valve codes and circuit details to Shree Hydraulics in Belagavi for product selection and quotation enquiries across India.

Request a quote