Yuken direct operated pressure relief valves

YCB-06 and YCB-10 relief valves

Compare cartridge, sub-plate and threaded relief valves. Choose the flow capacity, pressure setting and adjustment method for your circuit.

NG6 / NG10Two valve sizes
400 Kgf/cm²Maximum operating pressure
50 / 120 L/min.Maximum flow: YCB-06 / YCB-10
3 mountingsCartridge, sub-plate or threaded

Set the circuit’s pressure limit

Yuken YCB-06 and YCB-10 direct operated cartridge relief valves
Cartridge models from the manufacturer’s design 21 catalogue. Other mounting configurations differ in appearance.

YCB direct operated pressure relief valves limit excess pressure in hydraulic circuits. The size 06 and size 10 models have different flow capacities, with pressure options selected through the model code.

Choose a cartridge for the specified mounting cavity, a G sub-plate type or a T threaded type. Adjustment is available by screw or hand knob.

This page follows Yuken’s current design 21 catalogue. For an existing design 20 valve, send the complete nameplate code and mounting details so the replacement configuration can be checked.

Compare YCB-06 and YCB-10

ModelMaximum operating pressureMaximum flowCatalogue mass
YCB-06400 Kgf/cm²50 L/min.1.5 Kg.
YCB-10400 Kgf/cm²120 L/min.3.25 Kg.

The maximum operating pressure is distinct from the selected adjustment option. Check the minimum adjusting pressure and nominal override curves at the required flow before selection.

Pressure setting options

Model symbolMaximum adjustment pressure
A025 Kgf/cm²
A50 Kgf/cm²
B100 Kgf/cm²
C200 Kgf/cm²
D315 Kgf/cm²
E400 Kgf/cm²

These values identify the maximum adjustment pressure for each option. They do not imply adjustment from zero; refer to the catalogue characteristics.

Mounting code

No mounting symbol identifies the cartridge type. G identifies sub-plate mounting, while T identifies the threaded type.

Adjustment code

1 identifies the adjustment screw and 2 identifies the hand knob. The current catalogue uses design number 21.

Connections and sub-plates

ModelCartridge threadThreaded type portsSub-plate
YCB-06M28 x 1.51/4 BSP.FYCBM-06-20
1/4 BSP.F
YCB-10M35 x 1.51/2 BSP.FYCBM-10-20
1/2 BSP.F

The design 21 catalogue retains these design 20 sub-plate codes. Thread size alone does not establish fit: check the complete mounting cavity, port layout and dimensions in the catalogue.

Selection support

Send the model and mounting details

Include the required pressure and flow so the size, pressure option and adjustment method can be reviewed together.

  • Full YCB model code and design number
  • Required pressure setting and operating flow
  • Cartridge, G sub-plate or T threaded mounting
  • Adjustment screw or hand knob
  • Cavity or installation drawing and fluid details
  • Quantity and sub-plate requirement

YCB design 21 catalogue

Review model codes, pressure characteristics, mounting dimensions and cartridge installation data.

Download catalogue

Enquire about YCB-06 or YCB-10

Send your model code and circuit details to Shree Hydraulics in Belagavi for product selection and quotation enquiries across India.

Request a quote