Pressure compensator
Pump flow decreases as system pressure approaches the preset cut-off pressure while maintaining the set pressure.
Yuken piston pumps
Catalogue-backed specifications for Yuken A10 to A145 pumps, with control-type guidance and quotation support from Shree Hydraulics.
Product overview
The Yuken A Series covers eight variable displacement piston-pump sizes from A10 to A145. The catalogue describes high efficiency, low noise, energy-saving characteristics and low heat generation under its stated test conditions.
Pressure ratings, control availability and model coding vary across the range. Selection must be based on the complete model designation, required control function and operating conditions.
Pressure-compensator specifications
| Models | Geometric displacement | Minimum adjustable flow | Rated pressure | Intermittent pressure |
|---|---|---|---|---|
| A10 | 10.0 cm³/rev. | 2.0 cm³/rev. | 160 kgf/cm² | 210 kgf/cm² |
| A16 | 15.8 cm³/rev. | 4 cm³/rev. | 160 kgf/cm² | 210 kgf/cm² |
| A22 | 22.2 cm³/rev. | 6 cm³/rev. | 160 kgf/cm² | 160 kgf/cm² |
| A37 | 36.9 cm³/rev. | 10 cm³/rev. | 160 kgf/cm² | 210 kgf/cm² |
| A56 | 56.2 cm³/rev. | 12 cm³/rev. | 160 kgf/cm² | 210 kgf/cm² |
| A70 | 70.0 cm³/rev. | 30 cm³/rev. | 250 kgf/cm² | 280 kgf/cm² |
| A90 | 91.0 cm³/rev. | 56 cm³/rev. | 250 kgf/cm² | 280 kgf/cm² |
| A145 | 145.0 cm³/rev. | 83 cm³/rev. | 250 kgf/cm² | 280 kgf/cm² |
The table represents the single-pump pressure-compensator specifications in the supplied catalogue. Intermittent-pressure operation is restricted by duty conditions. Consult Yuken information for the applicable operating limits.
Pump flow decreases as system pressure approaches the preset cut-off pressure while maintaining the set pressure.
Provides remote control of full cut-off pressure through pilot-pressure control.
Output flow decreases as discharge pressure rises according to the preset input power.
Selection information
Send the complete model code or a clear nameplate photograph. The series includes multiple mounting, pressure range, port, shaft and control configurations.
Review the manufacturer document for the full control range, model designation, performance characteristics, dimensions, installation guidance and accessories.
Include the complete model, control code, pressure range, quantity and application details.